Our Products
Thanks to the great experience and hard work, we devoted our self to the technology innovation of energy saving preserving the environment with our products
Callora Heat Pumps – Best Investment for Your Home
![](https://www.callora.net/wp-content/uploads/Callora-Air-To-Water.jpg)
![](https://www.callora.net/wp-content/uploads/Callora-Air-To-Water-02.jpg)
AIR TO WATER HEAT PUMP
- Base frame and external panels made of polyester powder coated steel.
- Extremely compact structure ,easy demountable for access.
- High efficiency compressor with R410A refrigerant.
- Reverse cycle valve.
- Intelligent controller and adjustment by quickmind microprocessor with possibility or remote control.
- Careful protection functions such as :high pressure ,low pressure ,overheating , antifreezing , phase order ,discharge temp ,etc.
- Water side equipped with efficient tube in tube heat exchanger.
- Air exchanger(fan-coil)with hydrophilic coating.
- Automatic defrosting function included.
- Thermostatic expansion valve.
- General testing and operational test carried out for every unit before package in the factory.
![](https://www.callora.net/wp-content/uploads/Callora-Simming-Pool.jpg)
![](https://www.callora.net/wp-content/uploads/Callora-Simming-Pool-03.jpg)
SWIMMING POOL HEAT PUMP
- Base frame and external panels made of polyester powder coated steel.
- Extremely compact structure ,easy demountable for access.
- High efficiency compressor with R410A refrigerant.
- Reverse cycle valve Intelligent controller and adjustment by quickmind microprocessor with possibility or remote control.
- Careful protection functions such as :high pressure ,low pressure ,overheating ,overload , antifreezing , phase order , discharge temp , etc.
- Water side equipped with efficient tube in tube heat exchanger.
- Air exchanger(fian-coil)with hydrophilic coating.
- Automatic defrosting function included.
- Thermostatic expansion valve.
- General testing and operational test carried out for every unit before package in the factory.
![](https://www.callora.net/wp-content/uploads/Callora-Ground-Source.jpg)
![](https://www.callora.net/wp-content/uploads/Callora-Ground-Source-02.jpg)
GROUND SOURCE HEAT PUMP
- Base frame and external panels made of polyester powder coated steel.
- Extremely compact structure,lock door design,easy demountable for access.
- High efficiency compressor with R410A refrigerant.
- Reverse cycle valve.
- Super heater for sanitary hot water.
- Intelligent controller and adjustment by quickmind microprocessor with possibility or remote control.
- Careful protection functions such as : high pressure, low pressure, overheating ,overload , antifreezing , phase order , discharge temp , etc.
- Water flow switch for water flow protection.
- Water side equipped with efficient tube in tube heat exchanger.
- Thermostatic expansion valve.
- General testing and operational test carried out for every unit before package in the factory.
![](https://www.callora.net/wp-content/uploads/Callora-Water-to-Water.jpg)
![](https://www.callora.net/wp-content/uploads/Callora-Water-To-Water-02.jpg)
WATER TO WATER HEAT PUMP
- Base frame and external panels made of polyester powder coated steel.
- Extremely compact structure,lock door design,easy demountable for access.
- High efficiency compressor with R410A refrigerant.
- Reverse cycle valve.
- Super heater for sanitary hot water.
- Intelligent controller and adjustment by quickmind microprocessor with possibility or remote control.
- Careful protection functions such as :high pressure ,low pressure ,overheating ,overload , antifreezing , phase order , discharge temp , etc.
- Water flow switch for water flow protection.
- Water side equipped with efficient tube in tube heat exchanger.
- Thermostatic expansion valve.
- General testing and operational test carried out for every unit before package in the factory.
![](https://www.callora.net/wp-content/uploads/Callora-Air-to-Water-03.jpg)
![](https://www.callora.net/wp-content/uploads/Callora-Air-To-Water-04.jpg)
AIR TO WATER HEAT PUMP
- Base frame and external panels made of polyester powder coated steel.
- Extremely compact structure, easy demountable for access.
- High efficiency compressor with R410A refrigerant.
- Reverse cycle valve.
- Intelligent controller and adjustment by quickmind microprocessor with possibility or remote control.
- Careful protection functions such as :high pressure ,low pressure, overheating ,overload , antifreezing , phase order , discharge temp , etc.
- Water side equipped with efficient tube in tube heat exchanger or efficient tube in tube heat exchanger.
- Air exchnger(fan-coil)with hydrophilic costing.
- Automatic defrosting function included.
- Thermostatic expansion valve.
- General testing and operational test carried out for every unit before package in the factory.
![](https://www.callora.net/wp-content/uploads/Geothermal-Heat-Pump-01.jpg)
![](https://www.callora.net/wp-content/uploads/Callora-Geothermal-Heat-Pump.jpg)
GEOTHERMAL HEAT PUMP
- Base frame and external panels made of polyester powder coated steel.
- Extremely compact structure, lock door design,easy demountable for access.
- High efficiency compressor with R410A refrigerant.
- Reverse cycle valve.
- Super heater for sanitary hot water
- Intelligent controller and adjustment by quickmind microprocessor with possibility or remote control.
- Careful protection functions such as: high pressure, low pressure, overheating ,overload , antifreezing , phase order , discharge temp , etc.
- Water flow switch for water flow protection.
- Water side equipped with efficient tube in tube heat exchanger.
- Thermostatic expansion valve.
- General testing and operational test carried out for every unit before package in the factory.
![](https://www.callora.net/wp-content/uploads/Callora-ULTRA-THIN-FCU.jpg)
ULTRA THIN FCU
Cooling
Entering air temperature: Dry bulb 27℃, Wet bulb 19.5℃
Entering/out water temperature: 7℃/ 12?
Heating(1)
Entering air temperature: 20℃
Entering water temperature: 60℃, Same water flow rate as for the cooling
Heating(2)
Entering air temperature: 20℃
Entering water temperature: 70℃, Same water flow rate as for the cooling
Heating(3)
Entering air temperature: 20℃
Entering water temperature: 50℃, Same water flow rate as for the cooling
![](https://www.callora.net/wp-content/uploads/Callora-High-Wall-Mounted.jpg)
HIGH WALL MOUNTED FAN COIL UNIT
More about this product in our Catalog